Â
Electronic Digital Induction Water Descaler brief Introduction
Digital induction water descaler especially used at high hardness water treating. Good reasons of stable operation, long-time efficiency, long-distance effective signal transfer, which widely used at oily water, chemical industry, electricity, metallurgical industry, textile, and waste water.
Prevent Scale: Electronic Induction water treatment equipment forms electromagnetic field which regularly changes frequency and intensity. The field makes carbonate ion forming quantity Aragonite. When mineral content exceed the saturation solubility, carbonate ion will form the Aragonite preferential. The tendency of forming Calcite will reduce. The adhesion of Aragonite is weak and Aragonite is soft, flocculent and suspend on the water. It is easy to remove by water flow to reaches to the purpose of preventing scale.
Cleaning Scale: The scale which is on the surface of pipe disassembles to carbonate ion. The carbonate will form the Aragonite instead of Calcite in AV function. What's more, the scale will be off from pipe surface.
Kill bacterial: Scale is breeding ground of bacterial. If the scale is cleaned. That's means, the breeding ground of bacterial is cleaned. What's more, the electromagnetic field will damage the cell's cytoderm to cause difficult to survive. The solubility ability and dissolve of oxygen will improve in water after treated to inhibit anaerobic bacterial survive.
Descaling and prevent corrosion: Water rust will be cleaned in electromagnetic field. It will produce the Metal oxide film which can inhibit the water rust producing.
Electronic Digital Induction Water Descaler application
Â
Industry
oil field, oil-gather station, boiler, water-supply system
Color metallurgical, steel mill cooling system, heat exchange system, electricity cooling system.
Beer factory, beverage bottle clean plant.
Paper mill: evaporator, heat exchange
Vacuum boiler, vacuum pump
Commercial
Domestic boiler,wall-hanging boiler
Central air conditioning system: cooling recycling water
Swim pool heat-supply system, filtering and sterilizer equipment.
Irrigation
Pipe heat exchange system
Hot spring, ground water system
Punching and welding factory
Electronic Digital Induction Water Descaler Advantages
Â
1.Increase work efficiency
Increase heat exchange rate, good for keeping a stable process. It shows excellent benefits especially in chemical companies.
save energy
It reduces pump energy consumption, as thick water scale increase flow resistance. It also helps improve heat conductivity factor, increase heat using rate. Take 350MW electricity plant units as example. It requires coal consumption exceed 1.2T/H, whole year cost 0.6M$. Electrical induction descaler helps solve problems, avoid scale forming, which equals to save 0.6M$ per year.
Â
2.Save water resource
Electrical induction descaler bear much higher water hardness, concentration value reach to 4-6, compare with traditional treating ways.
Take chemical fertilizer company as example. Pipe diameter is 1100mm, recycling evaporation is 36 m3/h. Increase concentration value from 1.7 to 4.0, see below grid on water consumption:
Â
Concentration value | N=1.7 | N=4 |
Water supply(m3/h) | 80 | 44 |
Drain+wind loss(m3/h) | 47 | 11 |
If operation 8000hours per year, save water (80-44)c/h×8000h=28.8m3/year.
Save water cost 120K$.
3.Save chemical dose
Tradition way is to add chemical dose, Take coal-chemical company as example. Pipe diameter 800mm: water supply 60m3/h, concentration value 2.5, solution concentration 50mg/L, chemical cost: 2000$/ton, effective ingredients 50%.If operate 8000hours a year, chemical dosage:60m3/h×8000h×50mg/L÷50%÷2.5=19.2ton, save USD38,350 per year.
Â
4.Protect equipment
Electrical induction descaler helps equipment avoid corrosion in structure, extend lifetime 30%.
Â
5.Reduce incident
Electrical induction descaler has small size. No need cut pipeline, safe operation, weak electricity and magnetism, not harmful to human and equipment. It keep equipment away from corrosion failure.
Electronic Digital Induction Water Descaler working principle
The video of working principle:https://www.youtube.com/watch?v=2NCjU1QT8kw
Â
DESCALER creates a frequency-modulated electromagnetic field inside the supply pipe. This field forces the dissolved calcium (magnesium) and bicarbonate ions to create the crystallizing nuclei of calcium (magnesium) carbonate in the bulk of the water. These microcrystals continuously grow (the snowball effect) and they flow with the water in the form of suspended particles. Their size and shape is much different to those formed in untreated water, they don`t stick at the piping walls, heating elements of boilers or washing machines and they remain in suspension until discharged to drain.
Â
Water descaler control wayÂ
A completed unit consists of a control box, signal wire.
Â
control box create electromagnetic field. Signal wire wound around pipes. Connect with power supply, electromagnetic signal transfer deliveries to wire. Wire transfer electromagnetic to water.Â
Â
Dimension: https://www.youtube.com/watch?v=H9gMqXKWlKk
Main parameters include:
Material:Â | Metal Shell (Main board) |
Power input: | Â 20VACÂ Â 50HZ |
Ambient limitation:  | -10...+60°C |
Ambient relative humidity: |  ≤80% |
Pipe External temperature: | common cable wire <70ºC |
high-temperature allowance cable: | <130ºC |
Pipeline diameter:Â | OD15mm to1500mm |
Electronic Digital Induction Water Descaler Specification
Â
Model | Pipe diameter(mm) | Power (W) | Input Voltage |
CLDC-2.5CR | 65 | 2.5 | Â Â Â Â Â Â 220VAC 50 HZ |
CLDC-3CR | 80 | 2.5 | |
CLDC-4CR | 100 | 3.0 | |
CLDC-5CR | 125 | 3.5 | |
CLDC-6CR | 150 | 5.0 | |
CLDC-8CR | 200 | 13 | |
CLDC-10CR | 250 | 18 | |
CLDC-12CR | 300 | 26 | |
CLDC-14CR | 350 | 28 | |
CLDC-16CR | 400 | 33 | |
CLDC-18CR | 450 | 38 | |
CLDC-20CR | 500 | 42 |
 Electronic Digital Induction Water Descaler installation diagram
Remark: twist wire means wound wire.
Electronic Digital Induction Water Descaler installation site
Hard water treatment Application picture
Electronic Digital Induction Water Descaler installation notice
  1. Install at ventilate place, with 220VAC 50HZ power supply. Fasten Control box on the wall, or on water pipe. Keep away from big power appliance (2meters), to avoid magnetism signal interruption.
  2. Distance between control box and pipe not more than 2meters.
  3.Make sure pipe is straight, and appearance is clean, smooth, no thermal cover, painting.
  4.Fix wire part closet to the device on the water pipe.
  5. Fasten wire around pipe by mean of plastic clip.
  6.Wind wire based on right-hand magnetism law. Coil direction same as flow direction.
If pipe outside diameter (OD) <100mm, coil length>OD×8+1000(mm)
If pipe outside diameter (OD) ≥100mm, coil length>OD×8+1500(mm)
  7. Cover with plastic tape outside coil, in case loose or scrape.
  8. Users can add a protective fence for protection.
How to use:
Connect with power supply. Turn on main board power switch.
Green lights on indicates working condition.
MAKE SURE full water flow through water descaler.Â
Â
Comparison with Other Scale Treating Equipment
Â
Type | water condition | influence to equipment  | results | lifetime |
ion exchange | has pollution | rust equipment | only remove scale | several years |
chemical dosing | has pollution | rust equipment | remove scale, bacterial, algae | -- |
chemical cleaning | severe pollution | strongly rust equipment | only remove scale | -- |
statistic electricity | no pollution | rust equipment | not good result | 10years |
ion stick | no pollution | rust equipment | remove bacterial algae, not good at remove scale | 3-5years |
electric magnetic | no pollution | no pollution | remove scale, bacterial, algae | 15years |
Certificate
Â
Â
Â
Electronic Digital Induction Water Descaler brief Introduction
Digital induction water descaler especially used at high hardness water treating. Good reasons of stable operation, long-time efficiency, long-distance effective signal transfer, which widely used at oily water, chemical industry, electricity, metallurgical industry, textile, and waste water.
Prevent Scale: Electronic Induction water treatment equipment forms electromagnetic field which regularly changes frequency and intensity. The field makes carbonate ion forming quantity Aragonite. When mineral content exceed the saturation solubility, carbonate ion will form the Aragonite preferential. The tendency of forming Calcite will reduce. The adhesion of Aragonite is weak and Aragonite is soft, flocculent and suspend on the water. It is easy to remove by water flow to reaches to the purpose of preventing scale.
Cleaning Scale: The scale which is on the surface of pipe disassembles to carbonate ion. The carbonate will form the Aragonite instead of Calcite in AV function. What's more, the scale will be off from pipe surface.
Kill bacterial: Scale is breeding ground of bacterial. If the scale is cleaned. That's means, the breeding ground of bacterial is cleaned. What's more, the electromagnetic field will damage the cell's cytoderm to cause difficult to survive. The solubility ability and dissolve of oxygen will improve in water after treated to inhibit anaerobic bacterial survive.
Descaling and prevent corrosion: Water rust will be cleaned in electromagnetic field. It will produce the Metal oxide film which can inhibit the water rust producing.
Electronic Digital Induction Water Descaler application
Â
Industry
oil field, oil-gather station, boiler, water-supply system
Color metallurgical, steel mill cooling system, heat exchange system, electricity cooling system.
Beer factory, beverage bottle clean plant.
Paper mill: evaporator, heat exchange
Vacuum boiler, vacuum pump
Commercial
Domestic boiler,wall-hanging boiler
Central air conditioning system: cooling recycling water
Swim pool heat-supply system, filtering and sterilizer equipment.
Irrigation
Pipe heat exchange system
Hot spring, ground water system
Punching and welding factory
Electronic Digital Induction Water Descaler Advantages
Â
1.Increase work efficiency
Increase heat exchange rate, good for keeping a stable process. It shows excellent benefits especially in chemical companies.
save energy
It reduces pump energy consumption, as thick water scale increase flow resistance. It also helps improve heat conductivity factor, increase heat using rate. Take 350MW electricity plant units as example. It requires coal consumption exceed 1.2T/H, whole year cost 0.6M$. Electrical induction descaler helps solve problems, avoid scale forming, which equals to save 0.6M$ per year.
Â
2.Save water resource
Electrical induction descaler bear much higher water hardness, concentration value reach to 4-6, compare with traditional treating ways.
Take chemical fertilizer company as example. Pipe diameter is 1100mm, recycling evaporation is 36 m3/h. Increase concentration value from 1.7 to 4.0, see below grid on water consumption:
Â
Concentration value | N=1.7 | N=4 |
Water supply(m3/h) | 80 | 44 |
Drain+wind loss(m3/h) | 47 | 11 |
If operation 8000hours per year, save water (80-44)c/h×8000h=28.8m3/year.
Save water cost 120K$.
3.Save chemical dose
Tradition way is to add chemical dose, Take coal-chemical company as example. Pipe diameter 800mm: water supply 60m3/h, concentration value 2.5, solution concentration 50mg/L, chemical cost: 2000$/ton, effective ingredients 50%.If operate 8000hours a year, chemical dosage:60m3/h×8000h×50mg/L÷50%÷2.5=19.2ton, save USD38,350 per year.
Â
4.Protect equipment
Electrical induction descaler helps equipment avoid corrosion in structure, extend lifetime 30%.
Â
5.Reduce incident
Electrical induction descaler has small size. No need cut pipeline, safe operation, weak electricity and magnetism, not harmful to human and equipment. It keep equipment away from corrosion failure.
Electronic Digital Induction Water Descaler working principle
The video of working principle:https://www.youtube.com/watch?v=2NCjU1QT8kw
Â
DESCALER creates a frequency-modulated electromagnetic field inside the supply pipe. This field forces the dissolved calcium (magnesium) and bicarbonate ions to create the crystallizing nuclei of calcium (magnesium) carbonate in the bulk of the water. These microcrystals continuously grow (the snowball effect) and they flow with the water in the form of suspended particles. Their size and shape is much different to those formed in untreated water, they don`t stick at the piping walls, heating elements of boilers or washing machines and they remain in suspension until discharged to drain.
Â
Water descaler control wayÂ
A completed unit consists of a control box, signal wire.
Â
control box create electromagnetic field. Signal wire wound around pipes. Connect with power supply, electromagnetic signal transfer deliveries to wire. Wire transfer electromagnetic to water.Â
Â
Dimension: https://www.youtube.com/watch?v=H9gMqXKWlKk
Main parameters include:
Material:Â | Metal Shell (Main board) |
Power input: | Â 20VACÂ Â 50HZ |
Ambient limitation:  | -10...+60°C |
Ambient relative humidity: |  ≤80% |
Pipe External temperature: | common cable wire <70ºC |
high-temperature allowance cable: | <130ºC |
Pipeline diameter:Â | OD15mm to1500mm |
Electronic Digital Induction Water Descaler Specification
Â
Model | Pipe diameter(mm) | Power (W) | Input Voltage |
CLDC-2.5CR | 65 | 2.5 | Â Â Â Â Â Â 220VAC 50 HZ |
CLDC-3CR | 80 | 2.5 | |
CLDC-4CR | 100 | 3.0 | |
CLDC-5CR | 125 | 3.5 | |
CLDC-6CR | 150 | 5.0 | |
CLDC-8CR | 200 | 13 | |
CLDC-10CR | 250 | 18 | |
CLDC-12CR | 300 | 26 | |
CLDC-14CR | 350 | 28 | |
CLDC-16CR | 400 | 33 | |
CLDC-18CR | 450 | 38 | |
CLDC-20CR | 500 | 42 |
 Electronic Digital Induction Water Descaler installation diagram
Remark: twist wire means wound wire.
Electronic Digital Induction Water Descaler installation site
Hard water treatment Application picture
Electronic Digital Induction Water Descaler installation notice
  1. Install at ventilate place, with 220VAC 50HZ power supply. Fasten Control box on the wall, or on water pipe. Keep away from big power appliance (2meters), to avoid magnetism signal interruption.
  2. Distance between control box and pipe not more than 2meters.
  3.Make sure pipe is straight, and appearance is clean, smooth, no thermal cover, painting.
  4.Fix wire part closet to the device on the water pipe.
  5. Fasten wire around pipe by mean of plastic clip.
  6.Wind wire based on right-hand magnetism law. Coil direction same as flow direction.
If pipe outside diameter (OD) <100mm, coil length>OD×8+1000(mm)
If pipe outside diameter (OD) ≥100mm, coil length>OD×8+1500(mm)
  7. Cover with plastic tape outside coil, in case loose or scrape.
  8. Users can add a protective fence for protection.
How to use:
Connect with power supply. Turn on main board power switch.
Green lights on indicates working condition.
MAKE SURE full water flow through water descaler.Â
Â
Comparison with Other Scale Treating Equipment
Â
Type | water condition | influence to equipment  | results | lifetime |
ion exchange | has pollution | rust equipment | only remove scale | several years |
chemical dosing | has pollution | rust equipment | remove scale, bacterial, algae | -- |
chemical cleaning | severe pollution | strongly rust equipment | only remove scale | -- |
statistic electricity | no pollution | rust equipment | not good result | 10years |
ion stick | no pollution | rust equipment | remove bacterial algae, not good at remove scale | 3-5years |
electric magnetic | no pollution | no pollution | remove scale, bacterial, algae | 15years |
Certificate
Â
Â
Potassium Chloride is a common potash fertilizer. It can improve crops ability of drought resistance, cold resistance, lodging resistance,and pest disease resistance. It can also promote flowering and fruiting, and better use of nitrogen to increase protein content, and promote the production of sugar and starch.
Potassium Chloride |
|
Appearance |
White or red Powder/crystal/granular |
Total nutrient |
98% min |
K |
60% min |
Purity |
95% min |
Moisture |
1% max |
1. Not suitable for use in saline or alkaline lands and crops such as sugarcane, peach,grape,etc.
2. Chlorine-like crops: onion, spinach, celery, and cabbage
3. Chlorine-resistant crops: rice, wheat, barley, corn
Kcl /mop/potassium Chloride , Fertilizer/agricultal Grade Potassium Chloride , Flake Potassium Chloride With Low Price
Hebei Woldi Trading Co.,LTD , https://www.woldigroup.com