Model NO.: LF-302
Shape: Single-lens
Usage: Research
Principle: Optics
Principle of Optics: Differential Interference Contrast Microscope
Eyepiece: Wf10X/20
Plan Achromatic Objective: 4X, 10X, 40X, 100X(Oil)
Nospiece: Quintuple
Mechanical Movable Stage Size: 156*138mm
Mechanical Movable Stage Travel: 76*54mm
Interpupilary Distance: 52~75mm
Trinocular Tube: Inclined 30
Diopter Adjustment: 5 Diopter
Illumination: 6V/20W Halogen Bulb/ LED
Fluorescence Unit: Chroma Filter System UV, V, B, G
Trademark: Leader
Transport Package: Standard Exporting Packing
Specification: SGS
Origin: China
HS Code: 9011200000
Model NO.: LF-302
Shape: Single-lens
Usage: Research
Principle: Optics
Principle of Optics: Differential Interference Contrast Microscope
Eyepiece: Wf10X/20
Plan Achromatic Objective: 4X, 10X, 40X, 100X(Oil)
Nospiece: Quintuple
Mechanical Movable Stage Size: 156*138mm
Mechanical Movable Stage Travel: 76*54mm
Interpupilary Distance: 52~75mm
Trinocular Tube: Inclined 30
Diopter Adjustment: 5 Diopter
Illumination: 6V/20W Halogen Bulb/ LED
Fluorescence Unit: Chroma Filter System UV, V, B, G
Trademark: Leader
Transport Package: Standard Exporting Packing
Specification: SGS
Origin: China
HS Code: 9011200000
LED Illumination Trinocular Digital Fluorescence Biological Microscope (LF-302)Â
Fluorescence biological microscope (Fluorescence microscope): Fluorescence microscopy is an ultraviolet light source to irradiate the object to be seized, making it fluoresce, then observe the shape of the object and its location under a microscope. Fluorescence microscopy is used to study the absorption of intracellular material, transportation, chemicals distribution and positioning. Cells Some substances, such as chlorophyll, after ultraviolet irradiation fluoresce; while some, although the substance itself is not fluorescent, but if you use a fluorescent dye or fluorescent antibody staining, exposure to ultraviolet light can fluoresce, the fluorescence microscope is on the such material was one of the tools of qualitative and quantitative research.
Trinocular Fluorescence microscope is also named digital fluorescence microscopy, which can connect with digital camera and PC, this digital microscopy is widely used in biological area, especially in cell research and inspection in Hospitals, research institutes
Technical Data
Â
Eyepiece |
SWF10X/20 |
Objective lens |
4x, 10x, 40x, 100x(oil) |
Mechanical movable stage |
Size: 156*138mm, Travel: 76*54mm |
Interpupillary distance |
52mm-75mm |
Trinocular tube |
Inclined 30º.
|
Diopter adjustment |
±5 diopter |
Illumination |
6V/20W halogen bulb |
Fluorescence unit |
Mercury lamp house 100W/DC
Chroma filter system UV, V, B, G
|
Power supply |
110v-220v wide voltage |
Â
Â
Standard Delivery
Â
  Main unit: 1pcs
  4x, 10x, 40x, 100x(oil) plan achromatic objective: 1pcs each
  6V/20W Osram halogen bulb: 1pcs
  Blue filter: 1pcs
  Anti-dust cover: 1pcs
Â
Optional Accessories
Â
  2x, 20x, 60x plan achromatic objective
  0.5x, 1x C-mount camear adapter
  3.0M pixel digital camera
  5.0M pixel digital camera
  CCD camera
  Fluorescence analysis software
  LED light
  LED light
Picture: (inner package and outer package)
Â
Fluorescence biological microscope (Fluorescence microscope): Fluorescence microscopy is an ultraviolet light source to irradiate the object to be seized, making it fluoresce, then observe the shape of the object and its location under a microscope. Fluorescence microscopy is used to study the absorption of intracellular material, transportation, chemicals distribution and positioning. Cells Some substances, such as chlorophyll, after ultraviolet irradiation fluoresce; while some, although the substance itself is not fluorescent, but if you use a fluorescent dye or fluorescent antibody staining, exposure to ultraviolet light can fluoresce, the fluorescence microscope is on the such material was one of the tools of qualitative and quantitative research.
Trinocular Fluorescence microscope is also named digital fluorescence microscopy, which can connect with digital camera and PC, this digital microscopy is widely used in biological area, especially in cell research and inspection in Hospitals, research institutes
Technical Data
Â
Eyepiece |
SWF10X/20 |
Objective lens |
4x, 10x, 40x, 100x(oil) |
Mechanical movable stage |
Size: 156*138mm, Travel: 76*54mm |
Interpupillary distance |
52mm-75mm |
Trinocular tube |
Inclined 30º.
|
Diopter adjustment |
±5 diopter |
Illumination |
6V/20W halogen bulb |
Fluorescence unit |
Mercury lamp house 100W/DC
Chroma filter system UV, V, B, G
|
Power supply |
110v-220v wide voltage |
Â
Â
Standard Delivery
Â
  Main unit: 1pcs
  4x, 10x, 40x, 100x(oil) plan achromatic objective: 1pcs each
  6V/20W Osram halogen bulb: 1pcs
  Blue filter: 1pcs
  Anti-dust cover: 1pcs
Â
Optional Accessories
Â
  2x, 20x, 60x plan achromatic objective
  0.5x, 1x C-mount camear adapter
  3.0M pixel digital camera
  5.0M pixel digital camera
  CCD camera
  Fluorescence analysis software
  LED light
  LED light
Picture: (inner package and outer package)
Profile Extrusion Line ,Pe Extrusion Line ,Wpc Extrusion Line,Wpc Profile Production Line
Hitech Intelligent Machinery(Ningbo)Co., Ltd. , https://www.machinery-hitech.com