Fpd Detector Gas Chromatography Equipment with Automatic Online Detection Function

Model NO.: GC5890N
Trademark: Haida
Transport Package: Strong Wooden Case
Origin: Guangdong, China
FPD Detector Gas Chromatography Equipment With Automatic Online Detection Function
 

Descriprtion:
Optional multiple detector and filling column, shunt/unshunt capillary column injection system;Fully compatible with agilent 6890N gas chromatograph detector and related detector control board, chromatographic workstation and automatic sampler.Excellent performance, excellent performance, stable and reliable operation.

Application:
Petroleum, chemical industry, food, pharmaceutical, environmental protection, disease control, safety supervision, water, electricity, metallurgy, scientific research institute, quality inspection department.

Supporting products:
Headspace injector, gas generator, gas purifier, thermal analyzer, pyrolyzer, etc.

Performance:
1.New integrated digital electronic circuit, high control precision, stable and reliable performance, can reach the temperature control precision of 0.01 ºC.
2. Mixer has boot self-diagnosis function, stopwatch function convenient traffic (stable), timer function operation, power storage protection function, and key lock function, anti power mutation function, network data communication and remote control function.
3. The unique design of the sample system can lower the detection limit.
4. It can be used to select automatic/manual gas six-way injection valve sampler, headspace injector, thermo-analytical sampler, pyrolysis furnace sampler, methane converter, automatic sampler.
5. It is faster to control and stabilize the temperature of the furnace.
6. It can be installed with FID, TCD, FPD, NFD and PDHID detectors. All kinds of detectors can be independently controlled. The hydrogen flame detector can be easily disassembled and installed to facilitate cleaning or changing the nozzle.The stable time of thermal conductivity cell detector (TCD) is less than 20min.
7. It has automatic on-line detection function.


Parameter:
(The table parameters for the company Standard Model parameters, we support customer customization parameters)
Column temperature Box
Furnace size 28×30×18cm
Temperature range Room temperature 5~450ºC
Temperature setting 1 ºC; Program Set heating rate 0.1 ºC
Maximum heating rate 120ºC/ min
Temperature stability When the ambient temperature changes 1 ºC, it is 0.01 ºC
Program warming up 7 degree Program warming up
Operation Column loss compensation (dual channel)
Incoming Sample Port
A variety of feed-like port can be matched: filling column inlet, shunt/not shunt capillary inlet, the program temperature Leng head into the sample mouth.
Hydrogen Flame ionization detector (FID)
Maximum operating temperature 400ºC
Detection limit ≤5×10-12g/s [n-C16]
Baseline Drift ≤5×10-13A/30min
Noice ≤2×10-13A 
Dynamic linear Range ≥107
Thermal conductivity Pool Detector (TCD)
Maximum operating temperature 400ºC
Sensitivity ≥10000mv.ml/mg [n-C16]
Baseline Drift ≤100μV/30min
Noice ≤2×10-13A
Dynamic linear Range ≥104
Flame Photometric detectors (FPD)
Maximum operating temperature 250ºC
Detection limit ≤2x10-13 gs(P),≤5x10-11g/s(S)
Dynamic linear Range ≥103(P),≥102(S)
Noice ≤2×10-12A 
Baseline Drift ≤4x10-11A/30min
Electronic capture Detector (ECD)
Maximum operating temperature 350ºC
Detection limit ≤1x10-14g/ml(y-666)
Dynamic linear Range ≥104
Noice ≤20μA 
Baseline Drift ≤50μV/30min
Nitrogen and phosphorus detectors (NPD)
Maximum operating temperature 400ºC
Detection limit ≤5x10-13 gs(P),≤1x10-12g/s(N)
Dynamic linear Range ≥103(P),≥103(N)
Noice ≤4×10-13A 
Baseline Drift ≤2.5x10-12A/30min
Photoelectric ionization detector (PDHID)
Detection limit ≤5ppb
Anti-control software Optional configuration, Automatic injection B6891N
(The table parameters for the company Standard Model parameters, we support customer customization parameters)

Fpd Detector Gas Chromatography Equipment with Automatic Online Detection Function


Fpd Detector Gas Chromatography Equipment with Automatic Online Detection Function

 


The introduction of Haida

Haida products are widely used in paper products, packaging, ink printing, adhesive tapes, bags, footwear, leather products, environment, toys, baby products, hardware, electronic products, plastic products, rubber products and other industries, and are applicable to all scientific research units, quality inspection institutions and academic fields. Our products meet UL, ASTM, JIS, GB,SO, TAPPI, EN, DIN, BS and other domestic and international standards.

Fpd Detector Gas Chromatography Equipment with Automatic Online Detection Function

 
Packaging & Shipping:

Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.

Fpd Detector Gas Chromatography Equipment with Automatic Online Detection Function

 
After-service:

If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-con.





 