Fluoroplastic lined butterfly valve design tips

Fluoroplastic lined butterfly valve design skills: 1, Overview: With the rapid development of the modern petrochemical industry, some of the media used in special conditions have a very strong corrosive, even stainless steel valves and rubber lining, enamel valve Can not meet the needs. If the use of Hastelloy, Monel or Alloy No. 20 as the valve material, due to its large amount of Ni, Cr, Ti, Mo, Nb and Pt and other rare metals, its limited resources, expensive. According to the results of modern science and technology, fluorine plastic molecular structure with fluorocarbon bond and its shielding effect, with excellent corrosion resistance, high (low) temperature, non-sticking and electrical insulation, almost to resist all chemical media (Including hydrofluoric acid, concentrated sulfuric acid and aqua regia) corrosion. Fluoroplastics plastic processing principle, the fluorine plastic lined in the ordinary steel shell to cut off the metal contact with the strong corrosive media, both to solve the problem of low strength and can not withstand the high pressure of fluoroplastic, but also solved the Steel material is not resistant to corrosion problems. Fluoroplastic-lined valves have excellent heat and cold resistance, excellent electrical insulation and excellent chemical stability, and are resistant to all types of strong acids, strong bases and strong oxidizers. Low friction and very good self-lubricity , Long-term use in the range of - 195 ~ 200 ℃. 2, structure and design 2.1, the structure and the name of the main parts shown in Figure 1 and Figure 2. 1 Drive 2 Dust seal 3 O-ring 4 Butterfly 5 Butterfly lining 6 Seat lining 7 Body Figure 1 Double flanged butterfly valve 2.2 Scope Fluorine plastic lined butterfly valve Nominal pressure PN116 (fluorine Plastic pressure up to 215MPa). DN50 ~ 1 200. Valve temperature by the choice of different materials (metal materials and non-metallic materials) can withstand the temperature comprehensive assessment. Such as steel lined fluorine plastic (WCB + F46) material, the use of temperature - 29 ~ 150 ℃. Limit the maximum value does not exceed 150 ℃. Suitable medium for low viscosity acids and bases and other corrosive media, mainly refers to acidic, alkaline, organic and inorganic solvents and other corrosive media. Low viscosity is relatively high concentration of granular media, the fluorine plastic liner valves should try to avoid the use of solid particulate media. 3.3 Test Methods (1) Temperature test Temperature measurement range of room temperature to liquid nitrogen temperature, the use of thermocouple thermometer to measure the temperature signal through the digital multimeter measurement, acquisition and input measurement and control computer, displayed on the computer interface, and by the computer Automatically record and save. At the same time, the computer sends the temperature measurement to the temperature display on the instrument panel for on-site display. 2) Pressure test pressure measurement range of 0 ~ 10M Pa. The use of pointer precision pressure gauge and digital pressure gauge on the instrument panel on-site display of system pressure at the same time, the use of pressure transmitters to measure system pressure and converted to voltage signals measured by the digital multimeter to collect and input measurement and control computer , Displayed on the computer interface and automatically recorded and saved by the computer. (3) Level In order to ensure the liquid nitrogen level to meet the valve test requirements, the use of differential pressure transmitter to measure the liquid level. Measurement of electrical signals through the digital multimeter measurement, acquisition and input to the computer for display, and reminded filling liquid nitrogen and stop liquid nitrogen filling operation. (4) flow rate According to the different forms of valve sealing, the valve allows the amount of leakage is different. Soft seal structure of the valve, the amount of leakage should be zero. For hard-sealed valve itself is allowed to have a certain amount of leakage. Based on the above, two devices for measuring the flow rate are provided, one of which is a low-flow meter for measuring the leakage of a hard-sealed valve or a soft-sealed valve that allows a certain amount of leakage in a relatively abnormal working state. For a small amount of leakage, as the general flowmeter has been unable to detect, you need to observe and count the number of open-ended bubbles in the water to measure the number of leaks. Using computer data acquisition system to record the number of electrical pulses to achieve automatic counting. 4 Conclusion Based on the computer data acquisition system of low-temperature valve performance testing device, the thermocouple, pressure sensor, liquid level sensor and flowmeter of the various signals, pre-input into the computer, through the data acquisition software for data Display, store and print. The self-pressurizing system of liquid nitrogen tank can also be controlled according to the setting of relevant parameters. Liquid nitrogen can be filled into the low-temperature test tank. The test system uses centralized data monitoring, which not only enables the computer to issue commands to operate automatically, improve work efficiency, timeliness, accuracy and security of operation, but also facilitate the unified data storage and management. More Keyword Search: Lining Butterfly Valve

Shoe Cleaning Kit

A shoe cleaning kit is a set of tools and products that are used to clean and maintain shoes. The kit typically includes a variety of brushes and cloths, as well as cleaning solutions and polishes.
The brushes in a shoe cleaning kit may include a soft-bristled brush for gently removing dirt and dust, a stiff-bristled brush for removing stubborn stains and scuffs, and a polishing brush for buffing shoes to a shine. The cloths may include microfiber cloths for wiping away dirt and applying cleaning solutions, as well as polishing cloths for buffing shoes to a shine.
The cleaning solutions in a shoe cleaning kit may include a general-purpose cleaner for removing dirt and stains, a leather cleaner for cleaning and conditioning leather shoes, and a suede/nubuck cleaner for cleaning and restoring suede and nubuck shoes. The polishes may include a wax polish for adding shine and protection to leather shoes, and a suede/nubuck protector for protecting suede and nubuck shoes from water and stains.
Having a shoe cleaning kit on hand can help keep shoes looking their best and extend their lifespan.

The shoe cleaning kit includes a variety of Shoe Care products, such as cleaning agents, brushes, microfiber towels, etc., to solve the problems of shoe cleaning and maintenance in a one-stop manner.


Giant Athletic Shoe Cleaner kit is the elite shoe care product for athletics. Used on cleats, running /basketball sneakers or sandals, this shoe cleaning kit is formulated for all athletic footware and is safe to use on leather, canvas, nylon , rubber, vinyl and nylon mesh.

Shoe Cleaning Kit,Athletic Shoe Cleaning Set,Sneaker Shoe Cleaning,Shoe Cleaning Set

Jiangyin yinghuameng Houseware Co.,Ltd. , https://www.nbcare-guys.com